What does HRESULT 0x0004257A (VDS_S_RESYNC_NOTIFICATION_TASK_FAILED) mean?

 
Previous Next
VDS_S_REMOUNT_FAILED VDS_S_VSS_FLUSH_AND_HOLD_WRITES

VDS_S_RESYNC_NOTIFICATION_TASK_FAILED

This warning concerns notification reporting, not necessarily failure of the mirror or RAID-5 resynchronization itself. MS-VDS states that when the notification task fails, resynchronization notifications will not be sent for the affected mirror or RAID-5 volume. Clients that rely exclusively on progress callbacks can therefore appear stuck even though the underlying volume state continues to change.

Why this state matters

Volume modification notifications can carry a percentage-completed field for operations such as synchronization. A robust management client should retain the affected volume ID and be able to requery volume/plex state instead of assuming “no progress event” means “no progress.” The final operational state and provider/driver events are more important than the missing notification task.

Diagnostic focus

  • Record the volume and plex topology associated with the resynchronization operation.
  • Do not declare the resync failed solely because expected progress notifications stopped.
  • Query current volume/plex properties and health after allowing the underlying operation to proceed.
  • Inspect VDS/provider events for notification-task failure separately from disk I/O or plex regeneration errors.

Technical references

MS-VDS error codes · VDS_VOLUME_NOTIFICATION · Volume Plex Object · IVdsAdviseSink::OnNotify · VDS_NOTIFICATION


Looking for a different code? Search another status or error code.