What does HRESULT 0x8009302A (OSS_BERDER_DLL_NOT_LINKED) mean?

 
Previous Next
OSS_API_DLL_NOT_LINKED OSS_PER_DLL_NOT_LINKED

OSS_BERDER_DLL_NOT_LINKED

OSS_BERDER_DLL_NOT_LINKED (0x8009302A) is an OSS ASN.1 runtime result for BER/DER codec DLL absent. Encoding or decoding selects BER or DER, but the dynamic component implementing those rules is missing from the runtime package. Because selected encoding rule is central to this condition, Microsoft’s HRESULT range and the OSS Nokalva return-code documentation should be read together. Start the investigation by recording BER/DER module load error and architecture, then separate the encoded value from generated artifacts, call arguments, and the runtime package actually loaded by the process.

Neighboring statuses: OSS_BERDER_DLL_NOT_LINKED

BER and DER are related but not interchangeable in every profile: DER adds canonical restrictions used by certificates and signatures.

What the return code narrows down

At the BER/DER codec DLL absent boundary, capture the first OSS function returning the value and note whether the operation was encode, decode, copy, compare, constraint validation, or trace setup. Preserve the selected PDU, encoding rules, and generated code version paired with the module; otherwise an outer certificate or security wrapper may hide the useful codec result behind a generic failure.

Test one variable at a time

  1. decode a tiny definite-length DER sequence after packaging
  2. inspect loader dependencies
  3. verify the application did not deploy only PER support

Build a useful capture

RecordDiagnostic value
selected encoding ruleLocates the concrete message, allocation, module, or API boundary
BER/DER module load error and architectureSeparates payload-dependent behavior from build and process state
generated code version paired with the moduleMakes the comparison reproducible without rewriting the original artifact

Keep the original bytes or object graph unchanged while testing decode a tiny definite-length DER sequence after packaging. A change in BER/DER module load error and architecture after reload, plugin replacement, restart, or schema deployment is evidence about runtime state, not permission to discard the reproducer. When generated code version paired with the module points to one message, retain a cryptographic hash and the smallest safe sample instead of logging certificate, subscriber, credential, or private-key material.

Decision matrix

Controlled observationConclusion it supports
decode a tiny definite-length DER sequence after packagingA changed outcome isolates the first proposed control instead of a blind retry
selected encoding rule differs between success and failureThe difference localizes the BER/DER codec DLL absent boundary before unrelated settings are changed
An independent decoder accepts the same artifactInspect generated schema, selected rules, ABI, and optional OSS modules before declaring the bytes invalid
A fresh control object changes the outcomeInvestigate initialization, lifecycle, allocator ownership, configuration mutation, and concurrent access

Instrumentation

Record the full 32-bit HRESULT and lower OSS return number together with operation direction, symbolic PDU, encoding rule, byte count, and generated-table identifier. Where selected encoding rule can expose sensitive content, a hash plus a bounded structural excerpt is safer than the complete payload. Use BER/DER module load error and architecture together with OSS module paths and versions logged once per process so packaging differences can be correlated without flooding normal diagnostics.

Verify the repair: the result

Install the matching BER/DER module and validate canonical output where the protocol requires DER. A recovery test built around decode a tiny definite-length DER sequence after packaging should replay the same operation under the same schema and encoding rule, retain one deliberately invalid control, and verify ownership and cleanup after both outcomes. Success after an unexamined retry is not proof that selected encoding rule now satisfies the codec contract.

Technical references


Looking for a different code? Search another status or error code.