| Previous | Next |
| UTC_E_SETUP_TIMED_OUT | UTC_E_TRIGGER_NOT_FOUND |
UTC_E_TRIGGER_MISMATCH
Map the code to the scenario graph: trigger type binding
When UTC_E_TRIGGER_MISMATCH (0x87C51022) is returned, the producing layer is scenario state-machine trigger validation. A reliable investigation preserves the producing action before any cleanup runs. The rejected object or state is trigger type binding, and the specific condition is that a supplied trigger instance is not of the type required by the transition or forwarder. Keep this first HRESULT even if a later service call reports another error.
Time, event and forwarded triggers participate in a scenario state machine. Their type, ownership, source state and transition cardinality are configuration contracts; changing the observed event cannot repair an invalid graph.
Data needed for triage
| UTC diagnostic field | Value |
|---|---|
| Owning state or object | trigger type binding |
| Producing layer | scenario state-machine trigger validation |
| Do not confuse with | UTC_E_FORWARDER_PRODUCER_MISMATCH concerns the forwarding object rather than the trigger payload |
| Evidence to collect | expected/actual trigger type, producer, transition ID, serialized payload and configuration generation |
| Narrow comparison | construct the trigger through the expected producer while leaving payload values unchanged |
Reproduce without collateral changes
- Export the relevant
Microsoft-Windows-UniversalTelemetryClient/Operationalevents and preserve their ActivityId or request correlation alongside this result. - Capture expected/actual trigger type, producer, transition ID, serialized payload and configuration generation. Do this before restarting the service or deleting any working directory.
- Perform this one-variable comparison: construct the trigger through the expected producer while leaving payload values unchanged.
- After the comparison, record the next HRESULT and whether the requested session, action, trigger or output object was actually created.
Nearby result: UTC_E_FORWARDER_PRODUCER_MISMATCH — concerns the forwarding object rather than the trigger payload.
Platform-state note
Capture capability and identity state at the moment this result is returned. Session, container, service and destination state can change asynchronously, so a later successful query does not describe the state at failure.
Fix the contract
Bind each transition to the correct trigger factory and discard cached triggers after reload.
Technical references
- Microsoft Open Specifications: Windows error-code registry — reference for scenario state-machine trigger validation while interpreting this result.
- Microsoft: Universal Telemetry Client configuration diagnosis — reference for scenario state-machine trigger validation while interpreting this result.