What does HRESULT 0xC038002D (ERROR_VOLMGR_NUMBER_OF_MEMBERS_INVALID) mean?

 
Could be also:
ConstantTypeOS
STATUS_VOLMGR_NUMBER_OF_MEMBERS_INVALIDNTSTATUSWindows
Previous Next
ERROR_VOLMGR_NOTIFICATION_RESET ERROR_VOLMGR_NUMBER_OF_PLEXES_INVALID

ERROR_VOLMGR_NUMBER_OF_MEMBERS_INVALID

Identify the owner before touching the layout: volmgr number of members invalid

The practical meaning of ERROR_VOLMGR_NUMBER_OF_MEMBERS_INVALID (0xC038002D) is tied to dynamic-volume plex member descriptor and its backing extents: the plex layout declares a member count that is incompatible with its plex type or supplied member descriptors. The result does not, by itself, prove file-system corruption or physical-media failure.

Dynamic volumes are represented as packs containing disks and volumes; each volume has one or more plexes, and each plex is assembled from members and extents. Indices and counts are relative to the submitted layout generation, while configuration logs are replicated across participating dynamic disks. This object model determines which identifiers, counts and ownership state are meaningful while diagnosing this result.

A useful record contains more than the final UI symptom: retain the first failing call, target identity, topology and state transition before management software rescans the disks while diagnosing this result.

Minimum diagnostic set

Storage diagnostic fieldValue
Identity and generationpack ID, volume ID, plex index, member index, disk IDs, extent offsets, health state and regeneration percentage
Narrow experimentserialize the exact VM_VOLUME_LAYOUT buffer, validate every count and Size field, and compare it with a layout produced by a known-good management API
Closest comparisonERROR_VOLMGR_UNEXPECTED_DISK_LAYOUT_CHANGE
Owning objectdynamic-volume plex member descriptor and its backing extents
Rejected invariantthe plex layout declares a member count that is incompatible with its plex type or supplied member descriptors

Do not overwrite this result with a close, detach or rollback error. Preserve the causal order so the original storage contract remains visible for it.

Reproduce without destructive cleanup

  1. Associate this result with one caller, one transaction and one target UniqueId for it.
  2. Save the pre-call and post-call inventories, including pack ID, volume ID, plex index, member index, disk IDs, extent offsets, health state and regeneration percentage.
  3. Use this A/B case for it without touching unrelated storage: serialize the exact VM_VOLUME_LAYOUT buffer, validate every count and Size field, and compare it with a layout produced by a known-good management API for it.
  4. Validate both the HRESULT and the on-disk or provider state after the relevant reopen, remount or attach cycle for it.

A useful diagnostic fork is ERROR_VOLMGR_UNEXPECTED_DISK_LAYOUT_CHANGE versus it. This code concerns the plex layout declares a member count that is incompatible with its plex type or supplied member descriptors; the alternate code should remain observable after the fix, proving the application did not suppress the entire subsystem.

Mechanism-specific note

The count field is part of the layout contract rather than an advisory value. Verify it against the number of serialized descriptors and against the minimum geometry required by the selected layout type. Check multiplication and addition for overflow before allocating or copying the variable-length buffer, because a correctly sized allocation can still contain a logically impossible count.

Restore the contract

Rebuild the layout from enumerated objects and checked arithmetic rather than patching one serialized field; validate counts, indices, sizes, alignment and overflow before submission while diagnosing it. The result repair is incomplete until a fresh enumeration and new handle observe the corrected state.

  • the first retry uses newly enumerated identifiers rather than cached handles while diagnosing it.
  • The durable metadata or provider state agrees with the success returned after it.
  • A second run after close/reopen does not recreate the rejected the condition.
  • the nearby ERROR_VOLMGR_UNEXPECTED_DISK_LAYOUT_CHANGE path remains separately testable and separately logged.

Do not use it as a reason to edit dynamic-disk sectors, VHDX metadata, RCT sidecars or snapshot support files directly. Unsupported edits can turn a recoverable state mismatch into persistent corruption while diagnosing it.

Technical references


Looking for a different code? Search another status or error code.