| ippStsI18nMsgCatalogCloseErr | ippStsOFBSizeErr |
ippStsUnknownStatusCodeErr
This status belongs to status-code decoding rather than to the original primitive. It means the value passed to a status-string or message-catalog helper is not known by the linked IPP library.
Common causes are mixing headers and runtime libraries from different IPP versions, passing a non-IPP error code, or sign/width conversion around negative IppStatus values.
Diagnostic focus
- Log the raw signed integer and hexadecimal value of the code being decoded.
- Check that headers, import library, and runtime binaries come from the same IPP release.
- Do not infer a data-path failure from this status alone.
Intel IPP Error Reporting · Intel IPP status-to-message ID