Site icon EfmSoft

What does HRESULT 0x87C5100E (UTC_E_REESCALATED_TOO_QUICKLY) mean?

 
Previous Next
UTC_E_TRACE_NOT_RUNNING UTC_E_ESCALATION_ALREADY_RUNNING

UTC_E_REESCALATED_TOO_QUICKLY

Locate the rejected contract: per-scenario escalation cooldown

When UTC_E_REESCALATED_TOO_QUICKLY (0x87C5100E) is returned, the producing layer is DiagTrack scenario-definition processing. The symbolic name points to a narrow UTC contract that can be tested directly. The rejected object or state is per-scenario escalation cooldown, and the specific condition is that the trigger matched again before the configured minimum interval since the previous escalation elapsed. Keep this first HRESULT even if a later service call reports another error.

DiagTrack scenarios are configuration-driven state machines. A scenario definition, its diagnostic rules, referenced profiles, triggers and action graph must all come from a compatible configuration generation. Mixing authoring files or package versions can make an otherwise valid identifier unusable.

Capture checklist

UTC diagnostic fieldValue
Owning state or objectper-scenario escalation cooldown
Producing layerDiagTrack scenario-definition processing
Do not confuse withUTC_E_THROTTLED is event-rate throttling and need not be tied to a completed escalation
Evidence to collectscenario ID, escalation type, prior completion time, cooldown value, trigger timestamps and clock source
Narrow comparisonreplay the trigger after the cooldown expires without altering any other rule

Comparison with a passing case

  1. Freeze the failing scenario package, caller inputs and UTC service lifetime that produced this result.
  2. Collect the high-value state: scenario ID, escalation type, prior completion time, cooldown value, trigger timestamps and clock source.
  3. Use a passing control on the same Windows build, then replay the trigger after the cooldown expires without altering any other rule.
  4. Repeat once after normal teardown to prove the result is not caused by a stale handle or leftover run state.

Nearby result: UTC_E_THROTTLED — is event-rate throttling and need not be tied to a completed escalation.

Configuration-generation check

Hash the scenario, rules and referenced profile files used and record the UTC process start time. If files changed after the process loaded them, restart only after preserving the prior generation so the comparison remains auditable.

Resolution and regression test

Deduplicate the producer or tune the documented cooldown only when repeated captures are genuinely required.

Technical references


Looking for a different code? Search another status or error code.

Exit mobile version