| Previous | Next |
| UTC_E_ESCALATION_DIRECTORY_ALREADY_EXISTS | UTC_E_TIME_TRIGGER_ONLY_VALID_ON_SINGLE_TRANSITION |
UTC_E_TIME_TRIGGER_ON_START_INVALID
Map the code to the scenario graph: transition from the reserved _start state
UTC_E_TIME_TRIGGER_ON_START_INVALID has the unsigned value 0x87C51030. In UTC it comes from scenario state-machine trigger validation, where transition from the reserved _start state owns the decision. A reliable investigation preserves the producing action before any cleanup runs. The immediate contract failed because a time trigger was attached to a transition whose source is the initial _start state, so diagnosis should remain at that boundary until a controlled comparison crosses it.
Time, event and forwarded triggers participate in a scenario state machine. Their type, ownership, source state and transition cardinality are configuration contracts; changing the observed event cannot repair an invalid graph.
Data needed for triage
| UTC diagnostic field | Value |
|---|---|
| Owning state or object | transition from the reserved _start state |
| Producing layer | scenario state-machine trigger validation |
| Do not confuse with | UTC_E_TIME_TRIGGER_ONLY_VALID_ON_SINGLE_TRANSITION concerns one timer shared by multiple transitions |
| Evidence to collect | state graph, source/target states, trigger type, scenario schema and authoring-tool validation |
| Narrow comparison | move the same duration to a transition from a real runtime state |
Reproduce without collateral changes
- Associate this result with one request, one scenario version and one service process ID.
- Save state graph, source/target states, trigger type, scenario schema and authoring-tool validation and the first lower-level HRESULT if one exists.
- Change no policy, provider set or destination except for this test: move the same duration to a transition from a real runtime state.
- Compare the produced artifacts and operational events, not only the top-level return value.
Nearby result: UTC_E_TIME_TRIGGER_ONLY_VALID_ON_SINGLE_TRANSITION — concerns one timer shared by multiple transitions.
Platform-state note
Capture capability and identity state at the moment this result is returned. Session, container, service and destination state can change asynchronously, so a later successful query does not describe the state at failure.
Fix the contract
Model initial entry as an immediate transition and start timing only after the scenario enters a concrete state.
Technical references
- Microsoft Open Specifications: Windows error-code registry — reference for scenario state-machine trigger validation while interpreting this result.
- Microsoft: Universal Telemetry Client configuration diagnosis — reference for scenario state-machine trigger validation while interpreting it.
- Microsoft: Querying Windows Event Log
- Microsoft: Windows Performance Recorder
Looking for a different code? Search another status or error code.
