Site icon EfmSoft

What does HRESULT 0x87C51050 (UTC_E_FILTER_INVALID_FUNCTION) mean?

 
Previous Next
UTC_E_FILTER_VERSION_MISMATCH UTC_E_FILTER_INVALID_FUNCTION_PARAMS

UTC_E_FILTER_INVALID_FUNCTION

Read this as a lifecycle result: filter function lookup

When UTC_E_FILTER_INVALID_FUNCTION (0x87C51050) is returned, the producing layer is scenario filter parser and evaluator. Treat this HRESULT as a state-machine report, not as a generic telemetry outage. The rejected object or state is filter function lookup, and the specific condition is that the expression names a function absent from the supported function table. Keep this first HRESULT even if a later service call reports another error.

UTC filters are typed programs, not plain text searches. Parsing, command validation, name lookup, signature binding and evaluation are distinct phases. Capturing the normalized expression and inferred operand types is essential for a useful diagnosis.

Diagnostic record

UTC diagnostic fieldValue
Owning state or objectfilter function lookup
Producing layerscenario filter parser and evaluator
Do not confuse withUTC_E_FILTER_FUNCTION_RESTRICTED means the function exists but is disallowed in this context
Evidence to collectfunction spelling/case, namespace if any, filter version, argument list and client capability
Narrow comparisonreplace it with a documented function while preserving operand data

Isolate one changing condition

  1. Freeze the failing scenario package, caller inputs and UTC service lifetime that produced this result.
  2. Collect the high-value state: function spelling/case, namespace if any, filter version, argument list and client capability.
  3. Use a passing control on the same Windows build, then replace it with a documented function while preserving operand data.
  4. Repeat once after normal teardown to prove the result is not caused by a stale handle or leftover run state.

Nearby result: UTC_E_FILTER_FUNCTION_RESTRICTED — means the function exists but is disallowed in this context.

Typed-filter note

Save the filter after variable substitution and type inference, not only the authoring XML. A visually plausible expression can still fail because the runtime command table, scope or operand types differ from the authoring tool. Test with one synthetic event whose fields and types are known exactly.

Operational response

Correct the generated command or target a client version that supports the needed function.

Technical references


Looking for a different code? Search another status or error code.

Exit mobile version